Follow
Rosa Villa Sanz
Title
Cited by
Cited by
Year
SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain
A Altuna, E Bellistri, E Cid, P Aivar, B Gal, J Berganzo, G Gabriel, ...
Lab on a Chip 13 (7), 1422-1430, 2013
1242013
Inkjet-printed electrochemical sensors
A Moya, G Gabriel, R Villa, FJ del Campo
Current Opinion in Electrochemistry 3 (1), 29-39, 2017
1012017
Sensor contact lens, system for the non-invasive monitoring of intraocular pressure and method for measuring same
J Veciana, C Rovira, M Mas-Torrent, RV Sanz, JA Llobet, JC Pastor, ...
US Patent App. 12/996,300, 2011
1012011
Sensor contact lens, system for the non-invasive monitoring of intraocular pressure and method for measuring same
J Veciana Miró, C Rovira Angulo, M Mas-Torrent, R Villa Sanz, ...
101*2009
Bioimpedance dispersion width as a parameter to monitor living tissues
A Ivorra, M Genescà, A Sola, L Palacios, R Villa, G Hotter, J Aguiló
Physiological measurement 26 (2), S165, 2005
932005
High-resolution mapping of infraslow cortical brain activity enabled by graphene microtransistors
E Masvidal-Codina, X Illa, M Dasilva, AB Calia, T Dragojević, ...
Nature materials 18 (3), 280-288, 2019
842019
Flexible graphene solution‐gated field‐effect transistors: efficient transducers for micro‐electrocorticography
C Hébert, E Masvidal‐Codina, A Suarez‐Perez, AB Calia, G Piret, ...
Advanced Functional Materials 28 (12), 1703976, 2018
842018
Minimally invasive silicon probe for electrical impedance measurements in small animals
A Ivorra, R Gomez, N Noguera, R Villa, A Sola, L Palacios, G Hotter, ...
Biosensors and bioelectronics 19 (4), 391-399, 2003
842003
New technology for multi-sensor silicon needles for biomedical applications
A Errachid, A Ivorra, J Aguilo, R Villa, N Zine, J Bausells
Sensors and Actuators B: Chemical 78 (1-3), 279-284, 2001
842001
Study of functional viability of SU-8-based microneedles for neural applications
LJ Fernández, A Altuna, M Tijero, G Gabriel, R Villa, MJ Rodríguez, ...
Journal of Micromechanics and Microengineering 19 (2), 025007, 2009
812009
Easily made single-walled carbon nanotube surface microelectrodes for neuronal applications
G Gabriel, R Gómez, M Bongard, N Benito, E Fernández, R Villa
Biosensors and Bioelectronics 24 (7), 1942-1948, 2009
762009
SU-8 microprobe with microelectrodes for monitoring electrical impedance in living tissues
M Tijero, G Gabriel, J Caro, A Altuna, R Hernández, R Villa, J Berganzo, ...
Biosensors and Bioelectronics 24 (8), 2410-2416, 2009
702009
SU-8 based microprobes with integrated planar electrodes for enhanced neural depth recording
A Altuna, LM de la Prida, E Bellistri, G Gabriel, A Guimerá, J Berganzo, ...
Biosensors and Bioelectronics 37 (1), 1-5, 2012
682012
Mapping brain activity with flexible graphene micro-transistors
BM Blaschke, N Tort-Colet, A Guimerà-Brunet, J Weinert, L Rousseau, ...
2D Materials 4 (2), 025040, 2017
672017
Manufacturing and full characterization of silicon carbide-based multi-sensor micro-probes for biomedical applications
G Gabriel, I Erill, J Caro, R Gómez, D Riera, R Villa, P Godignon
Microelectronics Journal 38 (3), 406-415, 2007
642007
Peripheral nerve regeneration through microelectrode arrays based on silicon technology
X Navarro, S Calvet, M Butí, N Gómez, E Cabruja, P Garrido, R Villa, ...
Restorative neurology and neuroscience 9 (3), 151-160, 1996
641996
SU-8-based microneedles for in vitro neural applications
A Altuna, G Gabriel, LM de la Prida, M Tijero, A Guimerá, J Berganzo, ...
Journal of Micromechanics and Microengineering 20 (6), 064014, 2010
552010
Geometric correction factor for transepithelial electrical resistance measurements in transwell and microfluidic cell cultures
J Yeste, X Illa, C Gutiérrez, M Solé, A Guimerà, R Villa
Journal of Physics D: Applied Physics 49 (37), 375401, 2016
532016
Non-invasive intraocular pressure monitoring with a contact lens engineered with a nanostructured polymeric sensing film
V Laukhin, I Sánchez, A Moya, E Laukhina, R Martin, F Ussa, C Rovira, ...
Sensors and Actuators A: Physical, 2011
532011
Quantitative self-powered electrochromic biosensors
MA Pellitero, A Guimerà, M Kitsara, R Villa, C Rubio, B Lakard, ML Doche, ...
Chemical science 8 (3), 1995-2002, 2017
502017
The system can't perform the operation now. Try again later.
Articles 1–20