Follow
W Stuart Dols
W Stuart Dols
Verified email at nist.gov - Homepage
Title
Cited by
Cited by
Year
CONTAM 2.4 user guide and program documentation
GN Walton, WS Dols
US Department of Commerce, National Institute of Standards and Technology, 2005
403*2005
CONTAM User Guide and Program Documentation Version 3.2
WS Dols, BJ Polidoro
http://www.nist.gov/manuscript-publication-search.cfm?pub_id=918910, 2015
1482015
CONTAMW 2.0 User Manual
WS Dols, GN Walton
Multizone Airflow and Contaminant Transport Analysis Software, NISTIR-6921, 2002
1452002
Natural ventilation review and plan for design and analysis tools
SJ Emmerich, WS Dols, JW Axley
US Department of Commerce, Technology Administration, National Institute of …, 2001
1432001
Using CFD capabilities of CONTAM 3.0 for simulating airflow and contaminant transport in and around buildings
LL Wang, WS Dols, Q Chen
Hvac&R Research 16 (6), 749-763, 2010
1002010
Coupling the multizone airflow and contaminant transport software CONTAM with EnergyPlus using co-simulation
WS Dols, SJ Emmerich, BJ Polidoro
Building simulation 9 (4), 469-479, 2016
852016
CONTAMW 1.0 user manual: multizone airflow and contaminant transport analysis software
WS Dols, G Walton, KR Denton
612000
The relation of CO2 concentration to office building ventilation
A Persily, WS Dols
Air change rate and airtightness in buildings, 1990
611990
A tool for modeling airflow & contaminant transport
WS Dols
Ashrae Journal 43 (3), 35-43, 2001
562001
CONTAM 2.1 Supplemental user guide and program documentation
GN Walton, WS Dols, GN Walton
US Department of Commerce, National Institute of Standards and Technology, 2003
502003
A study of ventilation and carbon dioxide in an office building
SJ Nabinger, AK Persily, DW Stuart
ASHRAE Transactions 100 (2), 1264-1274, 1994
471994
Development and application of an updated whole-building coupled thermal, airflow and contaminant transport simulation program (TRNSYS/CONTAM)
WS Dols, L Wang, SJ Emmerich, BJ Polidoro
Journal of Building Performance Simulation 8 (5), 326-337, 2015
402015
Weather correlations to calculate infiltration rates for US commercial building energy models
LC Ng, NO Quiles, WS Dols, SJ Emmerich
Building and environment 127, 47-57, 2018
372018
CONTAMW 2.4 user manual
GN Walton, WS Dols
Gaithersburg, MD, USA, National Institute of Standards and Technology 286, 2008
362008
Using coupled energy, airflow and indoor air quality software (TRNSYS/CONTAM) to evaluate building ventilation strategies
WS Dols, SJ Emmerich, BJ Polidoro
Building Services Engineering Research and Technology 37 (2), 163-175, 2016
332016
Multi-zone modeling of size-resolved outdoor ultrafine particle entry into a test house
D Rim, A Persily, S Emmerich, WS Dols, L Wallace
Atmospheric Environment 69, 219-230, 2013
322013
A Study of Ventilation Measurement in an Office Building
WS Dols, AK Persily
Airflow Performance of Building Envelopes, Components, and Systems, ASTM STP …, 1995
291995
Building retrofits for increased protection against airborne chemical and biological releases
A Persily, RE Chapman, SJ Emmerich, WS Dols, H Davis, P Lavappa, ...
National Institute of Standards and Technology, Gaithersburg, MD, 2007
282007
An approach to the design of natural and hybrid ventilation systems for cooling buildings
J Axley, S Emmerich, S Dols, G Walton
Proc. Int. Conf. Indoor Air, 2002
272002
Air change effectiveness measurements in two modern office buildings
AK Persily, WS Dols, SJ Nabinger
Indoor air 4 (1), 40-55, 1994
271994
The system can't perform the operation now. Try again later.
Articles 1–20