Computer-assisted 3-dimensional reconstructions of scaphoid fractures and nonunions with and without the use of patient-specific guides: early clinical outcomes and … A Schweizer, F Mauler, L Vlachopoulos, L Nagy, P Fürnstahl The Journal of hand surgery 41 (1), 59-69, 2016 | 52 | 2016 |
Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides L Vlachopoulos, A Schweizer, M Graf, L Nagy, P Fürnstahl BMC musculoskeletal disorders 16 (1), 1-8, 2015 | 51 | 2015 |
Tumor resection at the pelvis using three-dimensional planning and patient-specific instruments: a case series T Jentzsch, L Vlachopoulos, P Fürnstahl, DA Müller, B Fuchs World journal of surgical oncology 14 (1), 1-12, 2016 | 50 | 2016 |
Complex osteotomies of tibial plateau malunions using computer-assisted planning and patient-specific surgical guides P Fürnstahl, L Vlachopoulos, A Schweizer, SF Fucentese, PP Koch Journal of Orthopaedic Trauma 29 (8), e270-e276, 2015 | 44 | 2015 |
Three-dimensional corrective osteotomies of complex malunited humeral fractures using patient-specific guides L Vlachopoulos, A Schweizer, DC Meyer, C Gerber, P Fürnstahl Journal of shoulder and elbow surgery 25 (12), 2040-2047, 2016 | 42 | 2016 |
Surgical treatment of long-bone deformities: 3D preoperative planning and patient-specific instrumentation P Fürnstahl, A Schweizer, M Graf, L Vlachopoulos, S Fucentese, S Wirth, ... Computational radiology for orthopaedic interventions, 123-149, 2016 | 36 | 2016 |
Computer algorithms for three-dimensional measurement of humeral anatomy: analysis of 140 paired humeri L Vlachopoulos, C Dünner, T Gass, M Graf, O Goksel, C Gerber, ... Journal of shoulder and elbow surgery 25 (2), e38-e48, 2016 | 30 | 2016 |
Accuracy and early clinical outcome of 3-dimensional planned and guided single-cut osteotomies of malunited forearm bones S Roner, L Vlachopoulos, L Nagy, A Schweizer, P Fürnstahl The Journal of hand surgery 42 (12), 1031. e1-1031. e8, 2017 | 29 | 2017 |
Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy SF Fucentese, P Meier, L Jud, GL Köchli, A Aichmair, L Vlachopoulos, ... Journal of Experimental Orthopaedics 7 (1), 1-7, 2020 | 25 | 2020 |
Introducing the lateral femoral condyle index as a risk factor for anterior cruciate ligament injury S Hodel, M Kabelitz, T Tondelli, L Vlachopoulos, R Sutter, SF Fucentese The American Journal of Sports Medicine 47 (10), 2420-2426, 2019 | 25 | 2019 |
Prediction of normal bone anatomy for the planning of corrective osteotomies of malunited forearm bones using a three‐dimensional statistical shape model F Mauler, C Langguth, A Schweizer, L Vlachopoulos, T Gass, M Lüthi, ... Journal of Orthopaedic Research 35 (12), 2630-2636, 2017 | 22 | 2017 |
Suture slippage in knotless suture anchors as a potential failure mechanism in rotator cuff repair K Wieser, M Farshad, L Vlachopoulos, K Ruffieux, C Gerber, DC Meyer Arthroscopy: The Journal of Arthroscopic & Related Surgery 28 (11), 1622-1627, 2012 | 20 | 2012 |
A scale-space curvature matching algorithm for the reconstruction of complex proximal humeral fractures L Vlachopoulos, G Székely, C Gerber, P Fürnstahl Medical image analysis 43, 142-156, 2018 | 17 | 2018 |
Is the contralateral tibia a reliable template for reconstruction: a three-dimensional anatomy cadaveric study P Schenk, L Vlachopoulos, A Hingsammer, SF Fucentese, P Fürnstahl Knee Surgery, Sports Traumatology, Arthroscopy 26 (8), 2324-2331, 2018 | 16 | 2018 |
Malpositioning of patient-specific instruments within the possible degrees of freedom in high-tibial osteotomy has no considerable influence on mechanical leg axis correction L Jud, P Fürnstahl, L Vlachopoulos, T Götschi, LC Leoty, SF Fucentese Knee Surgery, Sports Traumatology, Arthroscopy 28 (5), 1356-1364, 2020 | 15 | 2020 |
Joint-preserving tumour resection around the knee with allograft reconstruction using three-dimensional preoperative planning and patient-specific instruments L Jud, DA Müller, P Fürnstahl, SF Fucentese, L Vlachopoulos The Knee 26 (3), 787-793, 2019 | 15 | 2019 |
Assessment of the isometry of the anterolateral ligament in a 3-dimensional weight-bearing computed tomography simulation K Wieser, P Fürnstahl, F Carrillo, SF Fucentese, L Vlachopoulos Arthroscopy: The Journal of Arthroscopic & Related Surgery 33 (5), 1016-1023, 2017 | 15 | 2017 |
Mutation analysis of the growth factor genes PlGF, Flt1, IGF-I, and IGF-IR in intrauterine growth restriction with abnormal placental blood flow S Muetze, A Kapagerof, L Vlachopoulos, T Eggermann, P Kaufmann, ... The Journal of Maternal-Fetal & Neonatal Medicine 23 (2), 142-147, 2010 | 15 | 2010 |
Accuracy of three dimensional-planned patient-specific instrumentation in femoral and tibial rotational osteotomy for patellofemoral instability L Jud, L Vlachopoulos, S Beeler, T Tondelli, P Fürnstahl, SF Fucentese International orthopaedics 44 (9), 1711-1717, 2020 | 14 | 2020 |
Automatic string generation for estimating in vivo length changes of the medial patellofemoral ligament during knee flexion M Graf, S Diether, L Vlachopoulos, S Fucentese, P Fürnstahl Medical & Biological Engineering & Computing 52 (6), 511-520, 2014 | 14 | 2014 |