Fluid wall shear stress measurements in a model of the human abdominal aorta: oscillatory behavior and relationship to atherosclerosis JE Moore Jr, C Xu, S Glagov, CK Zarins, DN Ku Atherosclerosis 110 (2), 225-240, 1994 | 581 | 1994 |
Residual strain effects on the stress field in a thick wall finite element model of the human carotid bifurcation A Delfino, N Stergiopulos, JE Moore Jr, JJ Meister Journal of biomechanics 30 (8), 777-786, 1997 | 561 | 1997 |
Experimental and computational flow evaluation of coronary stents JL Berry, A Santamarina, JE Moore, S Roychowdhury, WD Routh Annals of biomedical engineering 28, 386-398, 2000 | 347 | 2000 |
Lymphatic system flows JE Moore Jr, CD Bertram Annual review of fluid mechanics 50 (1), 459-482, 2018 | 331 | 2018 |
Lymph flow, shear stress, and lymphocyte velocity in rat mesenteric prenodal lymphatics JB Dixon, ST Greiner, AA Gashev, GL Cote, JE Moore Jr, DC Zawieja Microcirculation 13 (7), 597-610, 2006 | 295 | 2006 |
Experimental investigation of the distribution of residual strains in the artery wall SE Greenwald, JE Moore Jr, A Rachev, TPC Kane, JJ Meister | 277 | 1997 |
Synergistic effects of fluid shear stress and cyclic circumferential stretch on vascular endothelial cell morphology and cytoskeleton S Zhao, A Suciu, T Ziegler, JE Moore Jr, E Bürki, JJ Meister, HR Brunner Arteriosclerosis, thrombosis, and vascular biology 15 (10), 1781-1786, 1995 | 260 | 1995 |
Computational analysis of flow in a curved tube model of the coronary arteries: effects of time-varying curvature A Santamarina, E Weydahl, JM Siegel, JE Moore Annals of biomedical engineering 26, 944-954, 1998 | 241 | 1998 |
Pulsatile flow visualization in the abdominal aorta under differing physiologic conditions: implications for increased susceptibility to atherosclerosis JE Moore Jr, DN Ku, CK Zarins, S Glagov | 224 | 1992 |
Biomedical technology and devices handbook G Zouridakis CRC press, 2003 | 223 | 2003 |
Determinants of valve gating in collecting lymphatic vessels from rat mesentery MJ Davis, E Rahbar, AA Gashev, DC Zawieja, JE Moore Jr American Journal of Physiology-Heart and Circulatory Physiology 301 (1), H48-H60, 2011 | 190 | 2011 |
Effects of stent design parameters on normal artery wall mechanics J Bedoya, CA Meyer, LH Timmins, MR Moreno, JE Moore Jr | 190 | 2006 |
Pulsatile velocity measurements in a model of the human abdominal aorta under resting conditions JE Moore Jr, DN Ku | 158 | 1994 |
Structural inhomogeneity and fiber orientation in the inner arterial media LH Timmins, Q Wu, AT Yeh, JE Moore Jr, SE Greenwald American Journal of Physiology-Heart and Circulatory Physiology 298 (5 …, 2010 | 156 | 2010 |
A device for subjecting vascular endothelial cells to both fluid shear stress and circumferential cyclic stretch JE Moore, E Bürki, A Suciu, S Zhao, M Burnier, HR Brunner, JJ Meister Annals of biomedical engineering 22, 416-422, 1994 | 150 | 1994 |
Hemodynamics in the abdominal aorta: a comparison of in vitro and in vivo measurements JE Moore Jr, SE Maier, DN Ku, P Boesiger Journal of Applied Physiology 76 (4), 1520-1527, 1994 | 146 | 1994 |
Fluid and solid mechanical implications of vascular stenting JE Moore, JL Berry Annals of biomedical engineering 30, 498-508, 2002 | 145 | 2002 |
Hemodynamics and wall mechanics of a compliance matching stent: in vitro and in vivo analysis JL Berry, E Manoach, C Mekkaoui, PH Rolland, JE Moore Jr, A Rachev Journal of Vascular and Interventional Radiology 13 (1), 97-105, 2002 | 145 | 2002 |
Compliant intraluminal stents JL Berry, JE Moore US Patent 6,206,910, 2001 | 142 | 2001 |
Increased artery wall stress post-stenting leads to greater intimal thickening LH Timmins, MW Miller, FJ Clubb Jr, JE Moore Jr Laboratory Investigation 91 (6), 955-967, 2011 | 136 | 2011 |