Folgen
Miguel Rodriguez Castillo
Miguel Rodriguez Castillo
Medical Physicist. Hospital Paitilla
Bestätigte E-Mail-Adresse bei cmpaitilla.com - Startseite
Titel
Zitiert von
Zitiert von
Jahr
Monte Carlo systems used for treatment planning and dose verification
L Brualla, M Rodriguez, AM Lallena
Strahlentherapie und Onkologie 193 (4), 243, 2017
632017
Monte Carlo simulation of TrueBeam flattening‐filter‐free beams using Varian phase‐space files: comparison with experimental data
MF Belosi, M Rodriguez, A Fogliata, L Cozzi, J Sempau, A Clivio, ...
Medical physics 41 (5), 051707, 2014
592014
A geometrical model for the Monte Carlo simulation of the TrueBeam linac
M Rodriguez, J Sempau, A Fogliata, L Cozzi, W Sauerwein, L Brualla
Physics in Medicine & Biology 60 (11), N219, 2015
482015
PENELOPE/PRIMO-calculated photon and electron spectra from clinical accelerators
L Brualla, M Rodriguez, J Sempau, P Andreo
Radiation Oncology 14, 1-10, 2019
412019
An anthropomorphic phantom for quality assurance and training in gynaecological brachytherapy
CE de Almeida, M Rodriguez, E Vianello, IH Ferreira, C Sibata
Radiotherapy and oncology 63 (1), 75-81, 2002
282002
Dosimetric parameters estimation using PENELOPE Monte-Carlo simulation code: Model 6711 a 125I brachytherapy seed
EAV Rodríguez, EPQ Alcón, ML Rodriguez, F Gutt, E de Almeida
Applied radiation and isotopes 63 (1), 41-48, 2005
272005
Implementation of in vivo dosimetry with Isorad™ semiconductor diodes in radiotherapy treatments of the pelvis
ML Rodríguez, E Abrego, A Pineda
Medical Dosimetry 33 (1), 14-21, 2008
242008
DPM as a radiation transport engine for PRIMO
M Rodriguez, J Sempau, C Bäumer, B Timmermann, L Brualla
Radiation oncology 13, 1-9, 2018
212018
PENLINAC: extending the capabilities of the Monte Carlo code PENELOPE for the simulation of therapeutic beams
ML Rodríguez
Physics in Medicine & Biology 53 (17), 4573, 2008
212008
Absorbed dose calculations in a brachytherapy pelvic phantom using the Monte Carlo method
ML Rodríguez, CE deAlmeida
Journal of Applied Clinical Medical Physics 3 (4), 285-292, 2002
172002
Study of the electron transport parameters used in penelope for the Monte Carlo simulation of Linac targets
M Rodriguez, J Sempau, L Brualla
Medical physics 42 (6Part1), 2877-2881, 2015
152015
Validation of a Monte Carlo framework for out-of-field dose calculations in proton therapy
M De Saint-Hubert, N Verbeek, C Bäumer, J Esser, J Wulff, R Nabha, ...
Frontiers in Oncology 12, 882489, 2022
142022
Treatment verification using Varian’s dynalog files in the Monte Carlo system PRIMO
M Rodriguez, L Brualla
Radiation Oncology 14, 1-7, 2019
132019
Many-integrated core (MIC) technology for accelerating Monte Carlo simulation of radiation transport: A study based on the code DPM
M Rodriguez, L Brualla
Computer Physics Communications 225, 28-35, 2018
112018
Primo User’s manual version 0.3. 1.1600
L Brualla, M Rodríguez, J Sempau
Strahlenklinik, Hufelandstrasse 55, 2018
102018
Study of the radiation field characteristics of a 137Cs irradiator by Monte Carlo simulation
ML Rodríguez, L del Risco Reyna, CE de Almeida
Health physics 85 (4), 433-437, 2003
102003
Experimental validation of an analytical program and a Monte Carlo simulation for the computation of the far out-of-field dose in external beam photon therapy applied to …
M De Saint-Hubert, F Suesselbeck, F Vasi, F Stuckmann, M Rodriguez, ...
Frontiers in Oncology 12, 882506, 2022
82022
Monte Carlo simulation of conical collimators for stereotactic radiosurgery with a 6 MV flattening‐filter‐free photon beam
M Hermida‐López, D Sánchez‐Artuñedo, M Rodríguez, L Brualla
Medical Physics 48 (6), 3160-3171, 2021
62021
The photon fluence non-uniformity correction for air kerma near Cs-137 brachytherapy sources
ML Rodriguez, CE DeAlmeida
Physics in Medicine & Biology 49 (9), 1705, 2004
42004
Monte Carlo simulation of a Varian's TrueBeam linac as a Clinac 2100: A feasibility study.
MLR Castillo, L Brualla, J Sempau
Radiotherapy and Oncology 152, S740-S740, 2020
12020
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20