Highly efficient nonrigid motion‐corrected 3D whole‐heart coronary vessel wall imaging G Cruz, D Atkinson, M Henningsson, RM Botnar, C Prieto Magnetic resonance in medicine 77 (5), 1894-1908, 2017 | 154 | 2017 |
Five‐minute whole‐heart coronary MRA with sub‐millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D‐PROST reconstruction A Bustin, G Ginami, G Cruz, T Correia, TF Ismail, I Rashid, R Neji, ... Magnetic resonance in medicine 81 (1), 102-115, 2019 | 143 | 2019 |
High‐dimensionality undersampled patch‐based reconstruction (HD‐PROST) for accelerated multi‐contrast MRI A Bustin, G Lima da Cruz, O Jaubert, K Lopez, RM Botnar, C Prieto Magnetic resonance in medicine 81 (6), 3705-3719, 2019 | 139 | 2019 |
Automatic CNN-based detection of cardiac MR motion artefacts using k-space data augmentation and curriculum learning I Oksuz, B Ruijsink, E Puyol-Antón, JR Clough, G Cruz, A Bustin, C Prieto, ... Medical image analysis 55, 136-147, 2019 | 120 | 2019 |
Accelerated motion corrected three‐dimensional abdominal MRI using total variation regularized SENSE reconstruction G Cruz, D Atkinson, C Buerger, T Schaeffter, C Prieto Magnetic resonance in medicine 75 (4), 1484-1498, 2016 | 119 | 2016 |
Free breathing whole-heart 3D CINE MRI with self-gated Cartesian trajectory M Usman, B Ruijsink, MS Nazir, G Cruz, C Prieto Magnetic resonance imaging 38, 129-137, 2017 | 85 | 2017 |
Sparsity and locally low rank regularization for MR fingerprinting G Lima da Cruz, A Bustin, O Jaubert, T Schneider, RM Botnar, C Prieto Magnetic resonance in medicine 81 (6), 3530-3543, 2019 | 80 | 2019 |
Multi‐parametric liver tissue characterization using MR fingerprinting: Simultaneous T1, T2, T2*, and fat fraction mapping O Jaubert, C Arrieta, G Cruz, A Bustin, T Schneider, G Georgiopoulos, ... Magnetic resonance in medicine 84 (5), 2625-2635, 2020 | 79 | 2020 |
Deep learning-based detection and correction of cardiac MR motion artefacts during reconstruction for high-quality segmentation I Oksuz, JR Clough, B Ruijsink, EP Anton, A Bustin, G Cruz, C Prieto, ... IEEE Transactions on Medical Imaging 39 (12), 4001-4010, 2020 | 79 | 2020 |
Water–fat Dixon cardiac magnetic resonance fingerprinting O Jaubert, G Cruz, A Bustin, T Schneider, B Lavin, P Koken, ... Magnetic resonance in medicine 83 (6), 2107-2123, 2020 | 78 | 2020 |
3D whole-heart isotropic sub-millimeter resolution coronary magnetic resonance angiography with non-rigid motion-compensated PROST A Bustin, I Rashid, G Cruz, R Hajhosseiny, T Correia, R Neji, R Rajani, ... Journal of Cardiovascular Magnetic Resonance 22 (1), 24, 2020 | 69 | 2020 |
Magnetic resonance fingerprinting using recurrent neural networks I Oksuz, G Cruz, J Clough, A Bustin, N Fuin, RM Botnar, C Prieto, AP King, ... 2019 IEEE 16th International Symposium on Biomedical Imaging (ISBI 2019 …, 2019 | 67 | 2019 |
Motion‐corrected simultaneous cardiac positron emission tomography and coronary MR angiography with high acquisition efficiency C Munoz, R Neji, G Cruz, A Mallia, S Jeljeli, AJ Reader, RM Botnar, ... Magnetic Resonance in Medicine 79 (1), 339-350, 2018 | 67 | 2018 |
Free‐running 3D whole heart myocardial T1 mapping with isotropic spatial resolution H Qi, O Jaubert, A Bustin, G Cruz, H Chen, R Botnar, C Prieto Magnetic Resonance in Medicine 82 (4), 1331-1342, 2019 | 58 | 2019 |
Optimized respiratory‐resolved motion‐compensated 3 DC artesian coronary MR angiography T Correia, G Ginami, G Cruz, R Neji, I Rashid, RM Botnar, C Prieto Magnetic Resonance in Medicine 80 (6), 2618-2629, 2018 | 57 | 2018 |
Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution H Qi, A Bustin, G Cruz, O Jaubert, H Chen, RM Botnar, C Prieto Magnetic resonance imaging 63, 159-169, 2019 | 55 | 2019 |
Rigid motion‐corrected magnetic resonance fingerprinting G Cruz, O Jaubert, T Schneider, RM Botnar, C Prieto Magnetic resonance in medicine 81 (2), 947-961, 2019 | 55 | 2019 |
Free-running cardiac magnetic resonance fingerprinting: Joint T1/T2 map and Cine imaging O Jaubert, G Cruz, A Bustin, T Schneider, P Koken, M Doneva, ... Magnetic resonance imaging 68, 173-182, 2020 | 53 | 2020 |
Coronary magnetic resonance angiography: technical innovations leading us to the promised land? R Hajhosseiny, A Bustin, C Munoz, I Rashid, G Cruz, WJ Manning, ... Cardiovascular Imaging 13 (12), 2653-2672, 2020 | 50 | 2020 |
3D free‐breathing cardiac magnetic resonance fingerprinting G Cruz, O Jaubert, H Qi, A Bustin, G Milotta, T Schneider, P Koken, ... NMR in Biomedicine 33 (10), e4370, 2020 | 49 | 2020 |