Folgen
Alexander Synek
Alexander Synek
Bestätigte E-Mail-Adresse bei ilsb.tuwien.ac.at
Titel
Zitiert von
Zitiert von
Jahr
The influence of bone density and anisotropy in finite element models of distal radius fracture osteosynthesis: evaluations and comparison to experiments
A Synek, Y Chevalier, SF Baumbach, DH Pahr
Journal of biomechanics 48 (15), 4116-4123, 2015
462015
The influence of distal screw length on the primary stability of volar plate osteosynthesis—a biomechanical study
SF Baumbach, A Synek, H Traxler, W Mutschler, D Pahr, Y Chevalier
Journal of Orthopaedic Surgery and Research 10, 1-8, 2015
402015
Effect of simulated metastatic lesions on the biomechanical behavior of the proximal femur
E Benca, A Reisinger, JM Patsch, L Hirtler, A Synek, S Stenicka, ...
Journal of Orthopaedic Research 35 (11), 2407-2414, 2017
332017
Evidence for habitual climbing in a Pleistocene hominin in South Africa
L Georgiou, CJ Dunmore, A Bardo, LT Buck, JJ Hublin, DH Pahr, ...
Proceedings of the National Academy of Sciences 117 (15), 8416-8423, 2020
252020
QCT-based finite element prediction of pathologic fractures in proximal femora with metastatic lesions
E Benca, A Synek, M Amini, F Kainberger, L Hirtler, R Windhager, W Mayr, ...
Scientific reports 9 (1), 10305, 2019
252019
Analysis of the three-dimensional anatomical variance of the distal radius using 3D shape models
SF Baumbach, J Binder, A Synek, FG Mück, Y Chevalier, E Euler, ...
BMC medical imaging 17 (1), 1-9, 2017
172017
Comparison of different microCT-based morphology assessment tools using human trabecular bone
L Steiner, A Synek, DH Pahr
Bone reports 12, 100261, 2020
142020
The effect of the extensor mechanism on maximum isometric fingertip forces: a numerical study on the index finger
A Synek, DH Pahr
Journal of biomechanics 49 (14), 3423-3429, 2016
142016
Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
A Synek, L Borgmann, H Traxler, W Huf, E Euler, Y Chevalier, ...
BMC Musculoskeletal Disorders 17 (1), 1-7, 2016
102016
Musculoskeletal models of a human and bonobo finger: parameter identification and comparison to in vitro experiments
A Synek, SC Lu, EE Vereecke, S Nauwelaerts, TL Kivell, DH Pahr
PeerJ 7, e7470, 2019
82019
Inverse remodelling algorithm identifies habitual manual activities of primates based on metacarpal bone architecture
A Synek, CJ Dunmore, TL Kivell, MM Skinner, DH Pahr
Biomechanics and Modeling in Mechanobiology 18, 399-410, 2019
82019
Towards optimization of volar plate fixations of distal radius fractures: Using finite element analyses to reduce the number of screws
A Synek, SF Baumbach, DH Pahr
Clinical Biomechanics 82, 105272, 2021
62021
Biomechanical testing of distal radius fracture treatments: boundary conditions significantly affect the outcome of in vitro experiments
A Synek, Y Chevalier, C Schröder, DH Pahr, SF Baumbach
Journal of applied biomechanics 32 (2), 210-214, 2016
62016
Multi-body simulation of a human thumb joint by sliding surfaces
A Synek, M Settles, G Stillfried
2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and …, 2012
62012
Plausibility and parameter sensitivity of micro-finite element-based joint load prediction at the proximal femur
A Synek, DH Pahr
Biomechanics and Modeling in Mechanobiology 17, 843-852, 2018
52018
A computational framework for canonical holistic morphometric analysis of trabecular bone
S Bachmann, CJ Dunmore, MM Skinner, DH Pahr, A Synek
Scientific Reports 12 (1), 5187, 2022
42022
Femoral strength can be predicted from 2D projections using a 3D statistical deformation and texture model with finite element analysis
L Steiner, A Synek, DH Pahr
Medical Engineering & Physics 93, 72-82, 2021
42021
Metacarpophalangeal joint loads during bonobo locomotion: model predictions versus proxies
A Synek, SC Lu, S Nauwelaerts, DH Pahr, TL Kivell
Journal of the Royal Society Interface 17 (164), 20200032, 2020
42020
A novel experimental design for the measurement of metacarpal bone loading and deformation and fingertip force
SC Lu, EE Vereecke, A Synek, DH Pahr, TL Kivell
PeerJ 6, e5480, 2018
32018
Thermal Effects during Bone Preparation and Insertion of Osseointegrated Transfemoral Implants
E Benca, B Ferrante, M Zalaudek, L Hirtler, A Synek, FM Kainberger, ...
Sensors 21 (18), 6267, 2021
22021
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20