Follow
Bayert Salverda
Bayert Salverda
Hennepin Healthcare Research Institute
Verified email at csbsju.edu
Title
Cited by
Cited by
Year
Head and thorax elevation during active compression decompression cardiopulmonary resuscitation with an impedance threshold device improves cerebral perfusion in a swine model …
JC Moore, N Segal, MC Lick, KW Dodd, BJ Salverda, MB Hinke, ...
Resuscitation 121, 195-200, 2017
472017
Controlled sequential elevation of the head and thorax combined with active compression decompression cardiopulmonary resuscitation and an impedance threshold device improves …
JC Moore, B Salverda, C Rojas-Salvador, M Lick, G Debaty, KG Lurie
Resuscitation 158, 220-227, 2021
382021
Effect of controlled sequential elevation timing of the head and thorax during cardiopulmonary resuscitation on cerebral perfusion pressures in a porcine model of cardiac arrest
C Rojas-Salvador, JC Moore, B Salverda, M Lick, G Debaty, KG Lurie
Resuscitation 149, 162-169, 2020
302020
Electrocardiographic diagnosis of acute coronary occlusion myocardial infarction in ventricular paced rhythm using the modified Sgarbossa criteria
KW Dodd, DL Zvosec, MA Hart, G Glass III, LE Bannister, RM Body, ...
Annals of Emergency Medicine 78 (4), 517-529, 2021
292021
Chest compliance is altered by static compression and decompression as revealed by changes in anteroposterior chest height during CPR using the ResQPUMP in a human cadaver model
N Segal, AE Robinson, PS Berger, MC Lick, JC Moore, BJ Salverda, ...
Resuscitation 116, 56-59, 2017
232017
Head and thorax elevation during cardiopulmonary resuscitation using circulatory adjuncts is associated with improved survival
JC Moore, PE Pepe, KA Scheppke, C Lick, S Duval, J Holley, B Salverda, ...
Resuscitation 179, 9-17, 2022
182022
Evaluation of the Boussignac Cardiac arrest device (B-card) during cardiopulmonary resuscitation in an animal model
JC Moore, L Lamhaut, A Hutin, KW Dodd, AE Robinson, MC Lick, ...
Resuscitation 119, 81-88, 2017
152017
Faster time to automated elevation of the head and thorax during cardiopulmonary resuscitation increases the probability of return of spontaneous circulation
JC Moore, S Duval, C Lick, J Holley, KA Scheppke, B Salverda, ...
Resuscitation 170, 63-69, 2022
132022
Improving post-cardiac arrest cerebral perfusion pressure by elevating the head and thorax
H Duhem, JC Moore, C Rojas-Salvador, B Salverda, M Lick, P Pepe, ...
Resuscitation 159, 45-53, 2021
112021
Relationship between hemodynamic parameters and cerebral blood flow during cardiopulmonary resuscitation
G Debaty, J Moore, H Duhem, C Rojas-Salvador, B Salverda, M Lick, ...
Resuscitation 153, 20-27, 2020
112020
Controlled progressive elevation rather than an optimal angle maximizes cerebral perfusion pressure during head up CPR in a swine model of cardiac arrest
JC Moore, B Salverda, M Lick, C Rojas-Salvador, N Segal, G Debaty, ...
Resuscitation 150, 23-28, 2020
112020
Device for elevating the head and chest for treating low blood flow states
KG Lurie, B Salverda
US Patent 10,406,069, 2019
62019
Controlled progressive elevation maximizes cerebral perfusion pressure during head up CPR in a swine model of cardiac arrest
JC Moore, B Salverda, M Lick, C Rojas-Salvador, G Debaty, N Segal, ...
Circulation 138 (Suppl_2), A17-A17, 2018
52018
Supraglottic airway devices variably develop negative intrathoracic pressures: A prospective cross-over study of cardiopulmonary resuscitation in human cadavers
J Holley, JC Moore, M Jacobs, C Rojas-Salvador, C Lick, BJ Salverda, ...
Resuscitation 148, 32-38, 2020
42020
3 clinical confirmation of improved likelihood of survival associated with the use of the head-up CPR bundle for non-shockable cardiac arrest presentations
P Pepe, J Moore, K Bachista, G Debaty, K Lurie, B Salverda, ...
Annals of Emergency Medicine 80 (4), S2, 2022
32022
353EMF elevation of the head and thorax during cardiopulmonary resuscitation improves cerebral blood flow in a swine model of prolonged cardiac arrest
KW Dodd, JC Moore, N Segal, MC Lick, BJ Salverda, MB Hinke, ...
Annals of Emergency Medicine 70 (4), S139-S140, 2017
22017
Hemodynamics, survival and neurological function with early versus delayed automated head-up CPR in a porcine model of prolonged cardiac arrest
P Pourzand, J Moore, A Metzger, B Salverda, M Suresh, S Arango, ...
Resuscitation 194, 110067, 2024
12024
Faster Time to Elevation of the Head and Thorax During Cardiopulmonary Resuscitation Increases the Likelihood of Return of Spontaneous Circulation After Out of Hospital Cardiac …
JC Moore, J Holley, KA Scheppke, B Salverda, C Rojas-Salvador, ...
CIRCULATION 142 (24), E495-E495, 2020
12020
Airway pressure is a valid surrogate for intrapleural pressure during CPR
Y Kwon, S McKnite, T Matsuura, A Merriam, B Salverda, D Yannopoulos
Circulation 126 (suppl_21), A267-A267, 2012
12012
The association of regional cerebral oximetry and neurologically intact survival in a porcine model of cardiac arrest
M Suresh, S Arango, J Moore, B Salverda, M Lick, C Rojas-Salvador, ...
Resuscitation Plus 17, 100539, 2024
2024