Dustin J. Tyler, PhD
Dustin J. Tyler, PhD
Kent H Smith Professor II of Biomedical Engineering, Case Western Reserve University, Louis Stokes
Verified email at case.edu - Homepage
TitleCited byYear
Stimuli-responsive polymer nanocomposites inspired by the sea cucumber dermis
JR Capadona, K Shanmuganathan, DJ Tyler, SJ Rowan, C Weder
science 319 (5868), 1370-1374, 2008
7622008
A neural interface provides long-term stable natural touch perception
DW Tan, MA Schiefer, MW Keith, JR Anderson, J Tyler, DJ Tyler
Science translational medicine 6 (257), 257ra138-257ra138, 2014
4062014
A versatile approach for the processing of polymer nanocomposites with self-assembled nanofibre templates
JR Capadona, O Van Den Berg, LA Capadona, M Schroeter, SJ Rowan, ...
Nature Nanotechnology 2 (12), 765, 2007
3582007
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
DJ Tyler, DM Durand
IEEE Transactions on Neural Systems and Rehabilitation Engineering 10 (4 …, 2002
3352002
Corrugated inter-fascicular nerve cuff method and apparatus
DJ Tyler, DM Durand
US Patent 5,634,462, 1997
2951997
Slowly penetrating inter-fascicular nerve cuff electrode and method of using
DJ Durand, DJ Tyler
US Patent 5,400,784, 1995
2561995
Flat interface nerve electrode and a method for use
D Tyler, DM Durand
US Patent 6,456,866, 2002
1652002
Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies
JP Harris, JR Capadona, RH Miller, BC Healy, K Shanmuganathan, ...
Journal of neural engineering 8 (6), 066011, 2011
1582011
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
JK Nguyen, DJ Park, JL Skousen, AE Hess-Dunning, DJ Tyler, SJ Rowan, ...
Journal of neural engineering 11 (5), 056014, 2014
1442014
Chronic response of the rat sciatic nerve to the flat interface nerve electrode
DJ Tyler, DM Durand
Annals of biomedical engineering 31 (6), 633-642, 2003
1292003
In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes
JP Harris, AE Hess, SJ Rowan, C Weder, CA Zorman, DJ Tyler, ...
Journal of neural engineering 8 (4), 046010, 2011
1282011
Systems and methods for performing prosthetic or therapeutic neuromuscular stimulation using a programmable universal external controller
ZP Fang, G Thrope, A Ignagni, S Pourmehdi, D Tyler, R Strother, ...
US Patent App. 09/822,761, 2003
1242003
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
MA Schiefer, KH Polasek, RJ Triolo, GCJ Pinault, DJ Tyler
Journal of neural engineering 7 (2), 026006, 2010
1122010
A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis
MA Schiefer, RJ Triolo, DJ Tyler
IEEE transactions on neural systems and rehabilitation engineering 16 (2 …, 2008
1112008
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
DJ Tyler, DM Durand
IEEE transactions on rehabilitation engineering 5 (1), 51-61, 1997
1091997
Systems and methods for performing prosthetic or therapeutic neuromuscular stimulation using an external, battery powered controller with power conservation features
ZP Fang, GB Thrope, A Ignagni, S Pourmehdi, D Tyler, RB Strother Jr, ...
US Patent 6,587,728, 2003
1072003
Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis
M Schiefer, D Tan, SM Sidek, DJ Tyler
Journal of neural engineering 13 (1), 016001, 2015
1022015
Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity
KH Polasek, HA Hoyen, MW Keith, RF Kirsch, DJ Tyler
IEEE transactions on neural systems and rehabilitation engineering 17 (5 …, 2009
1022009
Systems and methods for performing prosthetic or therapeutic neuromuscular stimulation using a universal external controller accommodating different control inputs and/or …
ZP Fang, GB Thrope, AR Ignagni, S Pourmehdi, DJ Tyler, RB Strother Jr, ...
US Patent 6,701,189, 2004
1012004
Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees
DW Tan, MA Schiefer, MW Keith, JR Anderson, DJ Tyler
Journal of neural engineering 12 (2), 026002, 2015
942015
The system can't perform the operation now. Try again later.
Articles 1–20