Follow
Guruprasad Rao
Guruprasad Rao
Helholtz Zentrum Dresden Rossendorf
Verified email at hzdr.de
Title
Cited by
Cited by
Year
Evaluation of CFRP-reference samples for porosity made by drilling and comparison with industrial porosity samples by means of quantitative X-ray computed tomography
B Plank, G Rao, J Kastner
7th International Symposium on NDT in Aerospace, 16-18, 2015
282015
Process monitoring of antisolvent based crystallization in low conductivity solutions using electrical impedance spectroscopy and 2-D electrical resistance tomography
G Rao, S Aghajanian, T Koiranen, R Wajman, L Jackowska-Strumiłło
Applied Sciences 10 (11), 3903, 2020
192020
Comparison of different segmentation methods for porosity evaluation in CFRP-reference samples with real porosity samples
G Rao, B Plank, J Kastner
Conference on Industrial Computed Tomography, 1-8, 2016
102016
Real-Time Fault Detection and Diagnosis of CaCO3 Reactive Crystallization Process by Electrical Resistance Tomography Measurements
S Aghajanian, G Rao, V Ruuskanen, R Wajman, L Jackowska-Strumillo, ...
Sensors 21 (21), 6958, 2021
82021
Is industrial tomography ready for augmented reality? a need-finding study of how augmented reality can be adopted by industrial tomography experts
Y Zhang, A Nowak, G Rao, A Romanowski, M Fjeld
International Conference on Human-Computer Interaction, 523-535, 2023
62023
Quantitative Evaluations with 2d Electrical Resistance Tomography in the Low-Conductivity Solutions Using 3d-Printed Phantoms and Sucrose Crystal Agglomerate Assessments
G Rao, MA Sattar, R Wajman, L Jackowska-Strumiłło
Sensors 21 (2), 564, 2021
62021
Application of the 2D-ERT to evaluate phantom circumscribed regions in various sucrose solution concentrations
G Rao, MA Sattar, R Wajman, L Jackowska-Strumiłło
2019 International Interdisciplinary PhD Workshop (IIPhDW), 34-38, 2019
62019
Damage characterization in SFRP using X-ray computed tomography after application of incremental and interrupted in situ quasi static tensile loading
G Rao, A Amirkhanov, D Salaberger, C Heinzl, J Kastner
7th conference on industrial computed tomography. Leuven (Belgium), 2017
62017
Talbot-Lau grating interferometer XCT for the quantitative characterization of damage in polymers after impact and static tensile testing
S Senck, D Salaberger, C Gusenbauer, B Plank, G Rao, J Kastner
19th World Conference on Non-Destructive Testing, WCNDT, 1-8, 2016
62016
Monitoring and Visualization of Crystallization Processes Using Electrical Resistance Tomography: CaCO3 and Sucrose Crystallization Case Studies
G Rao, S Aghajanian, Y Zhang, L Jackowska-Strumiłło, T Koiranen, ...
Sensors 22 (12), 4431, 2022
22022
Towards Real-Time Control of a Semibatch Crystallization Process by Electrical and Ultrasound Tomographic Techniques
S Aghajanian, G Rao, P Koulountzios, L Jackowska-Strumillo, ...
Chemical Engineering Transactions 86, 307-312, 2021
12021
Evaluation of a Testpiece for Porosity in Carbon Fibre Reinforced Polymers
J KASTNER, B PLANK, G RAO
measurement 1, 6, 2016
12016
4D Röntgen-Computertomografie mittels konventioneller Labor CTs: Möglichkeiten und Einschränkungen
B PLANK, D SALABERGER, G RAO, A AMIRKHANOV, J KASTNER
Three dimensional visualisation of barley corn seed and fish tissue using Talbot Lau grating interferometer.
G Rao, C Gusenbauer, S Senck, J Kastner
Talbot-Lau grating interferometer µXCT for quantitative characterization of polymeric structures by using phase and dark field contrast
J Kastner, C Gusenbauer, S Senck, G Rao
The system can't perform the operation now. Try again later.
Articles 1–15